Answer: According to the User Guides, the quantity of spare LED modules will vary by country. Please contact your regional ViewSonic sales office for further information.
DVLED Display with an entire column of unlit LED Modules. Answer: There may be poor connection or loose wiring with the connectors from the System Control Box to the LED Module adapter board. Solution The column's most bottom LED Module will need to be removed with the Vacuum Suction Tool in order to access the connectors. ...
The Cabinet installation order varies from the Wall-mount configuration. Please follow the steps in the respective order for the Floor Stand configuration: Cabinet B moved to the left side of the floor stand bracket Ensured rear-cabinet mounting bracket is securely placed onto the top cross beam of the floor stand Ensured notches under the ...
The Cabinet installation order varies from the Floor Stand configuration. Please follow the steps in the respective order for the Wall-mount configuration: Cabinet C moved to the center of the installation position, and Cabinet B placed to the left side of Cabinet C Hex wrench used to help align and ensure no tile-to-tile steps before engagi...
The System Control Box installation order is the same for the Wall-mount and Floor Stand configuration. Please follow the steps in the respective order for the System Control Box installation order: Seven system control box attachment points screwed down Control box Power cables: - Running from the back of the control box? - Running from ...
The LED Module installation order is the same for the Wall-mount and Floor Stand configuration. Please follow the steps in the respective order for the LED module installation order: Anti-static gloves worn Began handling with delicacy, following numbers marked on the box of each module Confirmed arrow facing upwards when installing the LE...
Answer: The number of Ethernet and Power cable sets that need to be attached from the System Control Box to DVLED Display Cabinets will vary depending on Cabinet quantity. Please refer to this link to find the Cabinet quantity for the appropriate model.
Answer: Before attaching the System Control Box Cover, connect the control box’s power cable to the control box cover's Power Button, and then install the cover with screws to complete the installation of the System Control Box.
Answer: There may be damage to the LED module's circuitry. Please check for unlit LEDs and refer to the LED Acceptance Criteria to replace appropriately. Related link: "Do I have to wear the anti-static gloves when installing LED modules for the DVLED Display?"
Answer: The correct orientation when installing the LED module is with the arrow (towards the center of the module's PCB side) facing up.