Power Receptacle Type L5-30P, EU, UK, AU, CN (may vary depending on region. double check power supply compatibility) Power Input Voltage Range 100-240 V ~ 50/60Hz Input Current 30A max @110V; 15A max@220V Leakage Current <0.25mA@240VAC Power Outlet quantity 1 (for 108", 135", 163"), 2 (for 216") *Recommended use on a singl...
The Cabinet installation order varies from the Wall-mount configuration. Please follow the steps in the respective order for the Floor Stand configuration: Cabinet B moved to the left side of the floor stand bracket Ensured rear-cabinet mounting bracket is securely placed onto the top cross beam of the floor stand Ensured notches under the ...
The LED Module installation order is the same for the Wall-mount and Floor Stand configuration. Please follow the steps in the respective order for the LED module installation order: Anti-static gloves worn Began handling with delicacy, following numbers marked on the box of each module Confirmed arrow facing upwards when installing the LE...
Solution Step 1: Wear anti-static gloves before handling the LED Modules. Step 2: Remove the Vacuum Suction Tool from the box and press its power switch to use it. Please charge it with the included power supply and make sure the vacuum suction tool is kept in a fully charged state. Step 3: Move the Vacuum Suction Tool to t...
DVLED Display with an entire column of unlit LED Modules. Answer: There may be poor connection or loose wiring with the connectors from the System Control Box to the LED Module adapter board. Solution The column's most bottom LED Module will need to be removed with the Vacuum Suction Tool in order to access the connectors. ...
Answer: "Hard calibration" is a form of hardware calibration that fine tunes the color and brightness for specific LED modules on the DVLED Display. Situations in which hard calibration may be required: LED Module position is changed or LED Module is replaced with a spare, LED Modules from a different color batch need to be used, LED M...
The Transfer Board (also known as a Transfer Card) is an internal component that facilitates signal connections between LED modules and the cabinet. Note: Current models have largely transitioned to "3-in-1 Boards." This article is for legacy product maintenance and technical reference only. Key Functions: Signal Supplementing: Routes ...
The Dehumidification service (or Dehumidification process) can be used to protect the LED module(s) by displaying a dark screen and gradually transitioning to a lighter screen. The concept is to gradually remove humidity by slowly heating up the circuitry - since a lighter colored screen uses more power than a darker colored screen. The total p...
To ensure a seamless installation, a comprehensive assessment of the mounting location, structural integrity, power supply, and site logistics is mandatory. Steps and Checklist: Installation Environment Define the exact mounting location and ensure there is ample room for equipment (e.g., tools, ladders, scaffolding). Power and C...
Proper tools are essential for precise alignment and preventing electronic damage. The list includes measurement instruments, power tools, and mandatory ESD protection. Steps: Prepare tools according to the following categories: Measurement & Alignment Self-leveling laser level. Stud sensor/finder (multi-depth/material). 4-vial...